Save Configuration Data Commands
● Save Scene Data: 280F 00701000
This command saves scene data to the SD card inserted in the Touch Finder as a file.
The destination for scene data is the following fixed directory on the SD card.
\Sensor name\SCN
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Scene number
Scene data file name
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Vision Sensor until there is a response.
420
Command Control
Vision Sensor command code
(4 bytes)
00701000
MRES
SRES
(1 byte)
(1 byte)
End code
Meaning
Command execution ended normally.
Command execution ended in an error.
Specifies the scene number (0 to 31) to be saved.
Specifies the file name when saving.
The file name extension (.scn) can be omitted.
Save scene number (4 bytes)
2 digits max.
Vision Sensor command code
(4 bytes)
00701000
Scene data file name
(4 to 64 bytes)
64 characters max.