Command code in
Command name
command area (hex)
00103010
Save Data in Sensor
00104010
Re-register Model (Search,
Shape search II, Sensitive
search, Color data)
00104020
Teaching (All Inspection Items) Executes teaching for all registered inspec-
00104021
Teaching (Filter/Position Com-
pensation Item)
00104022
Teaching (Inspection Item)
00104031
Re-register Reference Value
(Position Compensation Item)
00104032
Re-register Reference Value
(Inspection Item)
00108010
Set Registered Image
00108020
Acquire Registered Image
00109010
Echo
0010F010
Reset Vision Sensor
Important
After you execute the Reset command (0010F010 hex) for the Vision Sensor, turn OFF the EXE signal before the
Vision Sensor restarts. If you leave the EXE signal ON, the Vision Sensor will restart repeatedly.
● Commands to Get Status
Command code in
Command name
command area (hex)
00201000
Get Scene Number
● Commands to Set Status
Command code in
Command name
command area (hex)
00301000
Select Scene
FQ2-S/CH User's Manual
for Communications Settings
Function
This command saves the current setting data
(system data, scene groups, and calibration
data) in the Sensor.
This command re-registers the models for
registered Search, Shape search II, Sensitive
search, and Color data inspection items.
tion items.
Updates reference data for the specified
image adjustment processing item (filter item/
position compensation item).
Updates the reference data for the specified
inspection item.
Re-registers the reference value for the spec-
ified position compensation item based on
the previously loaded image.
Re-registers the reference values for the
specified inspection item based on the previ-
ously loaded image.
Sets the latest image or a specified logging
image as a registered image.
Loads a registered image saved to the SD
card or PC Tool as the measurement image.
This command returns any data (32 bits or 2
words) sent by the external device as-is.
Restarts the Sensor.
Function
Aquires the scene number currently being
used.
Function
Changes the scene number to be used.
Outputting Data and Controlling Operation through PROFINET
Reference
p.210
p.210
p.211
p.211
p.212
p.212
p.213
p.213
p.214
p.215
p.215
Reference
p.216
Reference
p.216