Omron FQ2-S Series User Manual page 128

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

[In/Out] − [I/O settings] − [Output data setting] − [Link data output/Fieldbus data output] −
[Output data set]
1
Press [0. Data 0].
2
Press [Multi-data].
3
Set the following items on the display to set expres-
sions.
Item
Description
Expression
Register the expression to use to output multiple data.
Examples:
Const.
Used to insert numbers and symbols into the expression.
Data
Used to select the inspection items for which to output data and insert the parameters to output
into the expression.
Example: Selecting Parameters for the Search Item at Inspection Item 0
Math.
Either of the following two functions can be inserted.
To register something to data 1 and higher, repeat this process.
The settings will be enabled after you restart the Sensor.
126
Controlling Operation and Outputting Data with PLC Link Communications
LPR (0, 3, I0.X, I0.Y)
LPC (0, I0.C, I0.X, I0.Y)
Inspection item: I0. Search
Judgement result: Judgement JG, Correlation: Corre. CR
• LPR function (order of the measurement data)
The measurement data is output in order.
Format: LPR(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
• LPC function (order of the detection points)
Data is output for each detected measurement point.
Format: LPC(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series