UPDATEREFITEM or URI
Re-register Reference Values (Inspection Item)
This command re-registers the reference value for the specified inspection item based on the previously loaded
image.
The model is not updated.
<Command Format>
U
P
D
A
or
U
R
I
Inspection
item number (2 digits max.)
Space
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
274
Command Control
T
E
R
E
F
I
CR
Delimiter
Specifies the item number of the inspection item that will have its reference values re-reg-
istered. (0 to 31)
Only "0" can be specified with the FQ2-S1 series.
T
E
M
Inspection
item number (2 digits max.)
Space
(0x20)
CR
Delimiter