Omron FQ2-S Series User Manual page 374

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

FINS Command Details
Executing Measurements: 280F 00101010
This command executes one measurement.
If Ethernet output is not set, only the measurement is performed.
If Ethernet output is set, the measurement is performed and the result is returned as response data.
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Measurement result
372
Command Control
Vision Sensor command code
(4 bytes)
00101010
MRES
SRES
(1 byte)
(1 byte)
End code
Meaning
Command execution ended normally.
Command execution ended in an error.
• Returns the measurement result as the response when data output is set. The measurement result is
not output when data output is not set.
Setting the Data to Output Automatically after Measurements: p. 169
• Each data item requires 4 bytes.
Up to 1,024 bytes of data can be received.
Vision Sensor command code
(4 bytes)
00101010
Measurement
result (1,024 bytes)
Measurement
result
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents