● Re-register Reference Values (Inspection Item): 280F 00104032
This command re-registers the reference values for the specified inspection item based on the previously
loaded image.
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Inspection item number
380
Command Control
Vision Sensor command code
(4 bytes)
00104032
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Specifies the item number of the inspection item that will have its reference values re-registered. (0 to 31)
Only "0" can be specified with the FQ2-S1 series.
Inspection item number (4 bytes)
Inspection item number from 0 to
31 (2 digits max.)
Vision Sensor command code
(4 bytes)
00104032