Omron FQ2-S Series User Manual page 349

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

LOGDATASAVE or LDS
Saves measurement data saved in the Sensor's memory by the logging function to the SD card inserted in the
Touch Finder as csv data.
The destination for measurement data is the following fixed directory on the SD card.
\Sensor name\LOGDATA
The file name is automatically created as follows.
YYYY_MM_DD-HH_mm_ss.csv
The date and time that make up the measurement data file name are not the date and time that the
measurement was performed, they are the date and time the measurement data file was saved from the
Sensor to the Touch Finder SD card by this command.
<Command Format>
L O G D A T
A
S A V E
or
C
L D S
R
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
Important
Do not turn off power to the Vision Sensor until there is a response.
FQ2-S/CH User's Manual
for Communications Settings
Time that the measurement data was saved to the Touch Finder SD card
Date that the measurement data was saved to the Touch Finder SD card
C
R