Omron FQ2-S Series User Manual page 295

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

ITEMDATA2 command or ID2
Acquire Inspection Item Text String Data
This command acquires the text string data of the specified inspection item.
<Command Format>
Command
I
T
E
M
D
A
or
I
D
2
Command
Inspection item
number
(2 digits max.)
Space
(0×20)
<Response Format>
When the Command Is Processed Normally
Acquired
CR
text string
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Acquired text string
FQ2-S/CH User's Manual
for Communications Settings
Inspection
item number
(2 digits max.)
T
A
2
Space
(0×20)
External reference
data number
(4 digits max.)
Space
(0×20)
Specifies the inspection item number. (0 to 31)
Specifies the external reference data number.
Section 9-2 External Reference Parameters
in Vision Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Returns the text string data for the specified inspection item.
Section 9-2 External Reference Parameters
in Vision Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
External reference
data number
(4 digits max.)
Space
(0×20)
CR
Delimiter
CR
Delimiter
Command Control