Omron FQ2-S Series User Manual page 40

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Note
This function can be used only when the input mode is set to Expanded Mode.
Changing the Types of Commands That Can Be Used: p. 45
Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Black
OUT0 (OR)
Orange
OUT1 (BUSY)
Timing Chart
IN0 to IN4 signals
are OFF
IN5 signal
BUSY signal
OR signal
1. Turn ON IN5 while IN0 to IN4 are OFF. If status is held while the BUSY signal is OFF, continuous
measurements will begin and the BUSY signal will remain ON while continuous measurements are being
performed.
2. Continuous measurements end when IN5 is turned OFF.
38
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
State
OFF
OFF
OFF
OFF
OFF
ON
--
--
ON
Allow 5 ms min. and then turn ON IN5.
OFF
ON
OFF
Start continuous measurements
ON
OFF
ON while measurements are
being processed (depends on
BUSY output conditions)
Description
Command parameters for continu-
ous measurements
Command input for continuous
measurements
Overall judgement (default assign-
ment)
Processing in progress (default
assignment)
Turned ON when overall judgement is NG
(OR output: ON for NG)
The signals shown at the left
are used.
Refer to the following informa-
tion for signal wiring.
Section 2 Installation
and Connections
in Vision Sensor
FQ2-S/CH Series
User's Manual
(Cat. No. Z337)
End continuous measurements
FQ2-S/CH User's Manual