Omron FQ2-S Series User Manual page 302

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

REGIMAGE or RID
Acquire Registered Image
This command loads a registered image saved to the SD card or PC Tool as the measurement image.
The registered image is the latest image or a logging image that has been assigned a number between 0 and
999 and has been registered in advance with the Set a Registered Image command.
Set a Registered Image p.271
<Command Format>
R
E
G
I
Space
or
(0x20)
R
I
D
Registered image number
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Registered image number Specifies the image to be loaded as the measurement image.
300
Command Control
Space
(0x20)
M
A
G
E
Registered image number
(3 digits max.)
CR
Delimiter
(3 digits max.)
The image is registered in advance with the Set a Registered Image command and
assigned a number. (0 to 999)
CR
Delimiter