Omron FQ2-S Series User Manual page 73

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Timing Chart
Example: Three Data Items Set for Parallel Data Output
Run Mode entered.
ON
RUN signal
OFF
ON
TRIG signal
OFF
ON
BUSY signal
OFF
OR signal
D0 to D15
signals
ON
GATE signal
OFF
ON
DSA signal
OFF
Timeout Time 1
If the DSA signal does not turn ON
within the specified time after
measurements are completed, a
timeout error will occur.
1
Turn ON the TRIG signal while the BUSY signal is OFF.
2
Measurement begins and the BUSY signal is turned ON during the measurement process.
3
At the same time or after the TRIG signal turns ON, the external device turns ON the DSA signal
to request data transmission.
*1
If you do not turn ON the DSA signal within the specified timeout time after measurements are completed, a timeout error will occur. (This
is timeout time 1.)
4
When the measurement has been finished, the measurement result is output using an OR signal,
and the BUSY signal is turned OFF.
*2
You can also set the [BUSY output] parameter so that the BUSY signal is turned OFF after the completion of data logging, image logging,
or displaying results.
5
The DSA signal is ON, and thus the D0 to D15 signals are output and the GATE signal turns ON.
6
When the DSA signal is turned OFF, the GATE signal turns OFF.
*3
If you do not turn OFF the DSA signal within the specified timeout time after the GATE signal turns ON, a timeout error will occur. (This is
timeout time 2.)
7
If more than one data item is being output for one measurement and you do not turn ON the DSA
signal within the specified timeout time after the GATE signal turns OFF, a timeout error will oc-
cur. (This is timeout time 3.)
FQ2-S/CH User's Manual
for Communications Settings
ON for 1 ms min.
ON while measurements are being processed
(depends on BUSY output conditions)
Overall judgement (Output when measurements have been
completed regardless of the DSA signal.)
Data 0
GATE
ON delay
If more than one data item is being output for one
measurement and the DSA signal does not turn
ON within the specified time after the GATE
signal turns OFF, a timeout error will occur.
Timeout Time 2
If the DSA signal does not turn OFF within the specified time
after the GATE signal turns ON, a timeout error will occur.
*1
*2
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
Data 1
Data 2
Timeout Time 3
*3
Setup Mode entere
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents