Omron FQ2-S Series User Manual page 413

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Set Terminal Offset Data: 280F 00504060
This command sets the value of the terminal offset data that is added to the IN0 to IN4 command parameters
when executing parallel commands.
When using parallel command scene changing, you can change the scenes to change to by changing the Set
Terminal Offset Data value.
Note
When using the Sensor in Expanded Mode while using the standard parallel interface of the Sensor, the range of
scene numbers that can be changed to with scene changing is limited to 0 through 15. By offsetting the command
parameter with this command, the scene can be changed to scene number 0 through 31.
Command Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00504060
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
Description
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Terminal offset value
Specifies the value to be added to the IN0 to IN4 command parameters when executing parallel com-
mands.
FQ2-S/CH User's Manual
for Communications Settings
Terminal offset value (4 bytes)
2 digits max.
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00504060
411
Command Control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents