Load All Model Dictionary Data
This command loads all model dictionary data that is stored on the SD card inserted in the Touch Finder.
The source for all model dictionary data is the following fixed directory on the SD card.
\Sensor name\DGP
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Vision Sensor)
First word of com-
mand area
12 to 15
+2
1101
+3
0000
+4
0000
+5
0000
+6
0000
:
:
+35
0000
*1
Loads the files named DictionaryAll_***.dgp saved on the SD card. (***: Specified file number)
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
1101
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0110
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
:
:
:
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0110
0000
0000
0000
0000
0000
0000
0000
Description
Command code
• EtherNet/IP, PROFI-
• PLC link
NET
File name to load
File number to load (0
64 characters max.
*1
to 999)
The file name exten-
sion (.dgp) can be
---
omitted.
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG