Omron FQ2-S Series User Manual page 82

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Re-registering the Model and Reference Color
This command is input from an external devices, such as a PLC, to re-register the models and reference colors
for registered inspection items based on the image that was just input.
Inspection items
Search, Shape Search II, Sensitive Search, Search Position Compensation, and
Shape Search Position Compensation
Color Data
Edge Position, Edge Width, Edge Pitch, Area, and Labeling
Parameters
Execution
Command
IN7
IN6
1
1001000
Timing Chart
RUN signal
IN0 to IN6 signals
IN7 signal
Allow 5 ms min.
and then turn ON IN7.
BUSY signal
ACK signal
Output Signals
Signal
Function
RUN
This signal is ON while the Sensor is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal is ON during re-registration of the model and reference color.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK output time.
80
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
IN5
IN4
IN3
Run Mode entered.
ON
OFF
0
1001000
ON for 1 ms min.
ON
OFF
ON
Command execution
OFF
ON
OFF
Re-registered data
Models
Reference color (hue, saturation, and brightness)
None
IN2
IN1
IN0
Setup Mode entered.
ACK output time
Input example
11001000
FQ2-S/CH User's Manual