Press [Position X X].
5
If the inspection item allows multi-point output,
press the number ([0] to [31]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to data 1 and higher, repeat this process.
The settings will be enabled after you restart the Sensor.
Assigning More Than One Inspection Result to the Same Output Data
You can assign more than one inspection result to the same data output to output all of the assigned results.
This is possible for the following inspection results.
• Parameters for the same inspection item: You can assign up to five inspection results.
• Inspection results that support multi-point output: You can assign inspection results within the specified range (0 to 31).
The following procedure shows how to assign more than one inspection result to data 0.
[In/Out] − [I/O setting] − [Output data setting] − [Link data output/Fieldbus data output] −
[Output data set]
1
Press [0. Data 0].
2
Press [Multi-data setting].
3
Set the following items on the display to set expres-
sions.
Item
Description
Expression
Register the expression to use to output multiple data.
Examples:
Const.
Used to insert numbers and symbols into the expression.
Data
Used to select the inspection items for which to output data and insert the parameters to output
into the expression.
Example: Selecting Parameters for the Search Item at Inspection Item 0
FQ2-S/CH User's Manual
for Communications Settings
LPR (0, 3, I0.X, I0.Y)
LPC (0, I0.C, I0.X, I0.Y)
Inspection item: I0. Search
Judgement result: Judgement JG, Correlation: Corre. CR
Outputting Data and Controlling Operation through PROFINET