● Acquire Camera Parameter: 280F 00401040
This command acquires the value of the specified camera parameter.
Camera parameter numbers: p. 219
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Camera parameter num-
*
ber
Acquired value
402
Command Control
Vision Sensor command code
(4 bytes)
00401040
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Specifies the number that corresponds to the camera parameter to be acquired.
Returns the specified camera parameter.
Camera parameter number
(4 bytes)
3 digits max.
Vision Sensor command code
(4 bytes)
00401040
Acquired value
(4 bytes)
Dependent on the
camera parameter
(1,000 times the
actual value)
FQ2-S/CH User's Manual