Omron FQ2-S Series User Manual page 324

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

OUTPUTTRANSSTATE or OTS
Set Communication Output Status
This command sets the output status (allowed/prohibited) for all the communications protocol.
Communications protocols with the output status set to prohibited will no longer output signals after being set
as such.
<Command Format>
O
U
T
P
Communications protocol status to be set
or
(1 digit max.)
O
T
S
Command
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Communications protocol
status to be set
322
Command Control
Command
U
T
T
R
A
N
CR
Delimiter
Space
(0x20)
Specifies the communications protocol status to be acquired.
0: Output prohibited status
1: Output allowed status
Communications protocol status
to be set (1 digit max.)
S
S
T
A
T
E
CR
Space
Delimiter
(0x20)
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series