Omron FQ2-S Series User Manual page 170

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

2
If you selected [No protocol (TCP)], select [TCP serv-
er] or [TCP client] for [Connection mode] and then
press [Back].
3
If you selected [No protocol (UDP)] or set [Connec-
tion mode] to [TCP client] in step 2, set the parame-
ters below.
Initial settings for no protocol communications
Items to set and their default values depend on the communication protocol used and connection mode set.
Communi-
Item
cation pro-
tocol used
and con-
nection
mode set
No protocol
Input port
(TCP) TCP
No.
server
No protocol
Output IP
(TCP) TCP
address
client
Output port
No.
No protocol
Input port
(UDP)
No.
Output IP
address
Output port
No.
168
Control and Output in No-Protocol (TCP) / No-Protocol (UDP)
Description
Sets the input port number to wait for a
connection request from the connected
external device (or client) such as a PLC.
In this connection mode, an FQ2 Sensor
serves as a TCP server and monitors this
port number to be ready for the connection
request from the client.
Sets the IP address of the connected exter-
nal device (PLC, etc.).
Sets the port number to be used for
exchanging data with the connected exter-
nal device (or client) such as a PLC.
Set the same port number as the port num-
ber set for the connected external device.
Sets the port number used for data inputs.
Set the same port number as the port num-
ber set for the connected external device.
Sets the IP address of the connected exter-
nal device (PLC, etc.).
Sets the port number used for data outputs.
Set the same port number as the port num-
ber set for the connected external device.
Setting range
0 to 65,535
Default: 9,876
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
Default: 10.5.5.111
0 to 65,535
Default: 9,600
0 to 65,535
Default: 9,600
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
Default: 10.5.5.111
0 to 65,535
Default: 9,600
FQ2-S/CH User's Manual