Omron FQ2-S Series User Manual page 100

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Assigning Inspection Results to Output Data
You can individually assign the parameters of the inspection items to output data (data 0 to data 31).
The following procedure shows how to assign the measured position X of [0. Search] to data 0 for a binary
output.
[In/Out] − [I/O setting] − [Output data setting] − [Link data output/Fieldbus data output] −
[Output data set]
1
Press [0. Data 0].
2
Press [Data setting].
3
Press [I0. Search].
4
Press [Position X X].
5
If the inspection item allows multi-point output,
press the number ([0] to [31]) of the inspection result
for which to output the data from the list of inspec-
tion results.
To register something to data 1 and higher, repeat this process.
The settings will be enabled after you restart the Sensor.
Assigning More Than One Inspection Result to the Same Output Data
You can assign more than one inspection result to the same data output to output all of the assigned results.
This is possible for the following inspection results.
• Parameters for the same inspection item: You can assign up to five inspection results.
• Inspection results that support multi-point output: You can assign inspection results within the specified range (0 to
31).
The following procedure shows how to assign more than one inspection result to data 0.
[In/Out] − [I/O setting] − [Output data setting] − [Link data output/Fieldbus data output] −
[Output data set]
1
Press [0. Data 0].
2
Press [Multi-data setting].
98
Controlling Operation and Outputting Data with EtherNet/IP Communications
FQ2-S/CH User's Manual
for Communications Settings