Omron FQ2-S Series User Manual page 394

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Set Communication Input Status: 280F 00307010
This command sets the input status (allowed/prohibited) of the communications port for the specified
communications protocol.
Communications protocols with the input status set to prohibited will no longer receive communications after
being set as such.
However, for inputs related to hardware (parallel TRIG signal and DSA signal), this setting is not applicable.
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Communications proto-
col type to be set
Setting value
392
Command Control
Vision Sensor command code
(4 bytes)
00307010
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Specifies the type of communications protocol to be set.
0: No protocol (TCP, UDP, FINS)
1: No protocol (RS-232C)
2: Parallel I/O
3: Fieldbus
5: PLC link
Sets the status of the communications protocol.
0: Input prohibited status
1: Input allowed status
Communications protocol type to
be set (4 bytes)
Communications protocol type to
be set (1 digit max.)
Vision Sensor command code
(4 bytes)
00307010
Setting value (4 bytes)
Communications protocol status
to be set (1 digit max.)