Omron FQ2-S Series User Manual page 129

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Expression Setting Example
This example registers an expression to output the following inspection results for data 0.
Inspection item: 0 Search
Parameters to output: Position X, Position Y, Reference SX, and Reference SY
Multi-point output setting: Multi-point output Check Box selected, Count = 4
LPR(0,I0.C
,
I0.X,I0.Y,I0.SX,I0.SY)
Function
data_A, data_B...data_d
Number_of_data
(Detection count)
Start_number
Output Results
The expression that is registered for data 0 assigns the data for 16 items (64 bytes) in the output area as shown
below.
Output area data
Output data 0 (4 bytes)
Output data 1 (4 bytes)
Output data 2 (4 bytes)
Output data 3 (4 bytes)
Output data 4 (4 bytes)
Output data 5 (4 bytes)
Output data 6 (4 bytes)
Output data 7 (4 bytes)
Output data 8 (4 bytes)
Output data 9 (4 bytes)
Output data 10 (4 bytes)
Output data 11 (4 bytes)
Output data 12 (4 bytes)
Output data 13 (4 bytes)
Output data 14 (4 bytes)
Output data 15 (4 bytes)
Note
• The inspection results will be output according to the sorting method that is set for multi-point output for the
inspection item.
• In order to output multiple detection results of the inspection items that can be output their results simultaneously,
from the [Inspection] menu of the targeted inspection item, press [Multi-point output] and select [Yes].
FQ2-S/CH User's Manual
for Communications Settings
Assigned data
I0.X[0] (Position X 1st point)
I0.Y[0] (Position Y 1st point)
I0.SX[0] (Reference SX 1st point)
I0.SY[0] (Reference SY 1st point)
I0.X[1] (Position X 2nd point)
I0.Y[1] (Position Y 2nd point)
I0.SX[1] (Reference SX 2nd point)
I0.SY[1] (Reference SY 2nd point)
I0.X[2] (Position X 3rd point)
I0.Y[2] (Position Y 3rd point)
I0.SX[2] (Reference SX 3rd point)
I0.SY[2] (Reference SY 3rd point)
I0.X[3] (Position X 4th point)
I0.Y[3] (Position Y 4th point)
I0.SX[3] (Reference SX 4th point)
I0.SY[3] (Reference SY 4th point)
Controlling Operation and Outputting Data with PLC Link Communications