● Change Scene Number: 280F 00301000
This command changes the scene number to use.
Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00301000
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Scene number
Specifies the scene number (0 to 31) to change to.
FQ2-S/CH User's Manual
for Communications Settings
Scene number (4 bytes)
Scene number to change to
(2 digits max.)
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00301000