Omron FQ2-S Series User Manual page 427

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Save All Setting Data: 280F 00705000
This command saves all setting data (all scene data, system data, calibration group data) for the Sensor to the
SD card inserted in the Touch Finder as a backup file.
The destination for backup data is the following fixed directory on the SD card.
\Sensor name\BKD
Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00705000
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
All setting data file name This command specifies the all setting data backup file name.
The file name extension (.bkd) can be omitted.
Important
Do not turn off power to the Vision Sensor until there is a response.
FQ2-S/CH User's Manual
for Communications Settings
All setting data file name
(4 to 64 byte)
64 characters max.
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00705000
425
Command Control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents