Omron FQ2-S Series User Manual page 219

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
Acquire Image Adjustment Item Data
This command acquires parameters and measurement values for a position compensation item or filter item.
Command (PLC to Vision Sensor)
First word of com-
mand area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
0001
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
FQ2-S/CH User's Manual
for Communications Settings
Bits
8 to 11
4 to 7
0 to 3
0000
0000
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0001
0000
0000
0100
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0001
0000
0000
0100
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Contents
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Contents
Command code
Position compensation item/filter item number
Data number
9-2 External Reference Parameters
in Vision Sensor FQ2-S/CH Series
User's Manual (Cat. No. Z337)
Contents
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Acquired data
(1,000 times the value)
217
Command Control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents