GETPOSFIGPARAM or GPFP
Acquire Measurement Region/Model Region Information Set for an Image Adjustment Item (Filter Item/Position
Compensation Item)
This command acquires the parameters for the measurement region or the model registration region set for an
image adjustment item (filter item/position compensation item).
Note
To check the figure number to be used when specifying a figure to change the settings of with the Set Image Adjust-
ment Item Figure command, do so using this command.
<Command Format>
G E
T
P
O
or
Space
(0x20)
G
P
F
P
Command
<Response Format>
When the Command Is Processed Normally
Parameter 1
,
Comma (fixed separator character)
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
286
Command Control
Command
S
F
I
G P A
Space
Figure number
(0x20)
(1 digit)
CR
Space
(0x20)
Region number (1 digit)
Image adjustment item (filter item/position compensation item) number (1 digit)
Parameter 2
,
...
Parameter 21
Comma (fixed separator character)
Image adjustment item
(filter item/position compensation item) number (1 digit)
R A M
Space
Region
(0x20)
number
(1 digit)
Space
(0x20)
Delimiter
CR
Space
Delimiter
(0x20)
CR
Figure
number
(1 digit)