Wiring
Color
Signal
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
Orange
OUT1 (BUSY)
Black
OUT0 (OR)
Timing Chart
• When inspection is OK
IN0 to IN4 signals
ON
IN5 signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
• When inspection is NG
IN0 to IN4 signals
ON
IN5 signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
FQ2-S/CH User's Manual
for Communications Settings
State
Description
OFF
Command parameters for trigger retry
(this command)
OFF
ON
ON
OFF
ON
Command input for trigger retry (this com-
mand)
--
Busy
--
Overall judgment (default)
IN5 ON after at least 5 ms
Retry starts
Scan
Scan
Scan
NG
NG
OK
Retry ends
IN5 ON after at least 5 ms
Retry starts
Scan
Scan
Scan
NG
NG
NG
Retry ends
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
The signals shown at the left
are used.
Refer to the following
information for signal wiring.
1 IN0, IN1 and IN4 are turned OFF, IN2
and IN3 are turned ON.
2 When IN5 is turned OFF > ON with
the BUSY signal OFF, trigger retry
inspection starts.
3 When retry inspection starts, the
BUSY signal turns ON.
4 When the overall judgment turns ON,
retry inspection ends and the BUSY
signal turns OFF.
5 After verifying that the BUSY signal
has turned ON > OFF, IN5 is turned
ON > OFF.
1 IN0, IN1 and IN4 are turned OFF, IN2
and IN3 are turned ON.
2 When IN5 is turned OFF > ON with
the BUSY signal OFF, trigger retry
inspection starts.
3 When retry inspection starts, the
BUSY signal turns ON.
Scan
4 IN5 is turned OFF and retry inspection
NG
ends. If retry inspection ends but the
overall judgment is NG, the OR signal
turns ON. (Output polarity: When ON
at NG)
Section 2 Installation
and Connections
in Vision Sensor
FQ2-S/CH Series
User's Manual
(Cat. No. Z337)