UPDATEREFPOS or URP
Re-register Reference Values (Position Compensation Item)
This command re-registers the reference value for the specified position compensation item based on the
previously loaded image.
<Command Format>
U
P
D
A
T
E
or
U
R
P
CR
Position compensation
item number (1 digit max.)
Space
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Position compensation
item number
FQ2-S/CH User's Manual
for Communications Settings
R
E
F
P
O
Delimiter
Specifies the item number of the position compensation item that will have its reference
values re-registered. (0 to 7)
S
CR
Delimiter
Position compensation
item number (1 digit max.)
Space
(0x20)
275