Omron FQ2-S Series User Manual page 152

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Item
Description
Math.
Either of the following two functions can be inserted.
To register something to data 1 and higher, repeat this process.
The settings will be enabled after you restart the Sensor.
● Expression Setting Example
This example registers an expression to output the following inspection results for data 0.
Inspection item: 0 Search
Parameters to output: Position X, Position Y, Reference SX, and Reference SY
Multi-point output setting: Multi-point output Check Box selected, Count = 4
LPR(0,I0.C
,
I0.X,I0.Y,I0.SX,I0.SY)
Function
Number_of_data
(Detection count)
Start_number
Output Results
The expression that is registered for data 0 assigns the data for 16 items (64 bytes) in the Input Area (output
area) as shown below.
Output area data
Output data 0 (4 bytes)
Output data 1 (4 bytes)
Output data 2 (4 bytes)
Output data 3 (4 bytes)
Output data 4 (4 bytes)
Output data 5 (4 bytes)
Output data 6 (4 bytes)
Output data 7 (4 bytes)
Output data 8 (4 bytes)
Output data 9 (4 bytes)
Output data 10 (4 bytes)
Output data 11 (4 bytes)
Output data 12 (4 bytes)
Output data 13 (4 bytes)
Output data 14 (4 bytes)
Output data 15 (4 bytes)
150
Outputting Data and Controlling Operation through PROFINET
• LPR function (order of the measurement data)
The measurement data is output in order.
Format: LPR(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
• LPC function (order of the detection points)
Data is output for each detected measurement point.
Format: LPC(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
data_A, data_B...data_d
Assigned data
I0.X[0] (Position X 1st point)
I0.Y[0] (Position Y 1st point)
I0.SX[0] (Reference SX 1st point)
I0.SY[0] (Reference SY 1st point)
I0.X[1] (Position X 2nd point)
I0.Y[1] (Position Y 2nd point)
I0.SX[1] (Reference SX 2nd point)
I0.SY[1] (Reference SY 2nd point)
I0.X[2] (Position X 3rd point)
I0.Y[2] (Position Y 3rd point)
I0.SX[2] (Reference SX 3rd point)
I0.SY[2] (Reference SY 3rd point)
I0.X[3] (Position X 4th point)
I0.Y[3] (Position Y 4th point)
I0.SX[3] (Reference SX 4th point)
I0.SY[3] (Reference SY 4th point)
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents