The communications protocol types are defined by the following numbers.
Communications
Communications type
protocol No.
0
No protocol (Ethernet)
1
No protocol (RS-232C)
2
Parallel I/O
3
Fieldbus
4
Reserved
5
PLC link
Acquire Communication Output Status
This command acquires the output status (allowed/prohibited) for all of the communications protocol set with
the Set Communication Output Status command.
Command (PLC to Vision Sensor)
First word of com-
mand area
12 to 15
+2
0111
+3
0000
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
0111
+3
0000
+4
0000
+5
0000
+6
0000
+7
0000
FQ2-S/CH User's Manual
for Communications Settings
No-protocol (UDP)
No-protocol (TCP)
No-protocol (FINS/TCP)
EtherNet/IP
PROFINET
PLC Link (SYSMAC)
PLC Link (MELSEC)
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0010
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Remarks
Results in an error when speci-
fied.
Description
Command code
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG
Acquired communications protocol status
0: Output prohibited status
1: Output allowed status
229
Command Control