Omron FQ2-S Series User Manual page 355

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

<Confirmation command format>
Before loading all setting data for the Sensor in binary data format, the Sensor checks whether or not it can
receive binary data.
P
R
E
B
K
D
<Confirmation command response format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Execution command format>
Loads all setting data for the Sensor in binary data format.
B
K
D
L
O
A
<Execution command response format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
File size scheduled to be sent
BKD data (binary)
FQ2-S/CH User's Manual
for Communications Settings
File size scheduled to be sent
L
O
A
D
B
Space
(0x20)
BKD data (binary)
D
B
Space
(0x20)
Number of bytes of all setting data for the Sensor scheduled to be sent (integer
type)
All setting data for the Sensor to be loaded (binary data)
CR
Delimiter
CR
Delimiter
353
Command Control

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents