Omron FQ2-S Series User Manual page 392

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Acquire Execution Mode: 280F 0020F000
Acquires the FQ2 execution status (execution mode).
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Execution mode
*
The execution mode is classified into the following modes depending on the FQ2 execution status.
• Run mode:
The mode to run actual measurements. I/O is possible with external devices such as a PLC.
• Stop mode: This mode is for monitoring/controlling the output status of the parallel signals through communication commands only.
Therefore, I/O that is unrelated to parallel terminal control is not possible.
• Input:
• Output: Parallel signal output is possible. Data output is not possible.
• Adjust mode: The status where Touch Finder is connected and the Setup display is displayed.
This mode is for configuring settings and making adjustments, so measurement processing, I/O signals from external
devices, and command input are not possible.
• IO monitor setup mode:The status where Touch Finder is connected and the IO monitor in the Setup display is displayed.
390
Command Control
Vision Sensor command code
(4 bytes)
0020F000
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
This command acquires the FQ2 execution mode
1: Run mode
2: Stop mode
10: Adjust mode
11: IO monitor setup mode
Parallel signal input is not possible. Command input is not possible. (However, the terminal status monitor, set-
ting commands can be used)
Vision Sensor command code
(4 bytes)
0020F000
*
.
Execution mode
(4 bytes)
Execution mode
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents