MODE
Set Execution Mode
Sets the FQ2 execution status (execution mode).
Note
When using commands (Set Terminal Status/Batch Set Terminal Status/Batch Set DO Status) to control the ON/
OFF status of the parallel I/O terminals with communication commands, change the FQ2 to stop mode with this
command.
<Command Format>
Execution mode
Command
(1 digit max.)
M
O
D
E
Space
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Execution mode
*
The execution mode is classified into the following modes depending on the FQ2 execution status.
• Run mode:
The mode to run actual measurements. I/O is possible with external devices such as a PLC.
• Stop mode: This mode is for monitoring/controlling the output status of the parallel signals through communication commands only.
Therefore, I/O that is unrelated to parallel terminal control is not possible.
• Input:
Parallel signal input is not possible. Command input is not possible. (However, the terminal status monitor, set-
ting commands can be used)
• Output: Parallel signal output is possible. Data output is not possible.
FQ2-S/CH User's Manual
for Communications Settings
CR
Delimiter
Specifies the FQ2 execution mode
1: Run mode
2: Stop mode
*
to be set.
321
Command Control