Omron FQ2-S Series User Manual page 148

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Parameter
Description
Output handshake Set whether to synchronize with the external
device when data is output.
No: Measurement results are output without
synchronizing with the external device.
Yes: Measurement results are output while syn-
chronizing with the external device.
Output data size
Set the size of the data that is to be output as
the measurement result.
Any changes in the setting are applied when
the Sensor is restarted.
Set the same value as the parameters set in the
external device.
Refreshing task
Set the communications cycle for PROFINET
IO communications for the Vision Sensor.
period
Timeout
This parameter is displayed and can be set only
when [Output handshake] is set to [Yes].
A timeout error will occur if there is no response
from the external device within the time that is set.
146
Outputting Data and Controlling Operation through PROFINET
Data Output after Measurements
When Handshaking Is Disabled: p. 117
Data Output after Measurements
When Handshaking Is Enabled: p. 117
Note
If the total size of the data that is specified as
output data exceeds the size that is set here, all
of the data will not be output at the same time,
but will be separated over more than one cycle.
Order of Output of Measurement Data
and Characters: p. 24
Important
Important
• Set this parameter to the same value as you
set for the requested packet interval (RPI) in
the external device.
• This parameter is necessary for the FQ2 to cycle
at the update cycle set in the Engineering Tool.
• If the value in the FQ2 is longer than the
value in the external device, cyclic data
exchange will not be performed according to
the expected communications cycle.
• The smaller the setting of this parameter is,
the more the measurement processing time
will be affected. For the lowest setting of
1 ms, the processing time will increase by
approximately 5% to 20%.
• From when measurements are completed
until the DSA Bit turns ON
• From when the GATE flag turns ON until the
DSA Bit turns OFF
• From when the GATE flag turns OFF until the
DSA Bit turns ON
Setting range
• Yes
• No
(default: Yes)
32 bytes, 64 bytes, 128 bytes, or 256 bytes
(default: 32 bytes)
1 to 10,000 ms (default: 16 ms)
0.1 to 120.0 s (default: 10.0 s)