Omron FQ2-S Series User Manual page 368

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Execution command format>
Outputs all image data stored in the Sensor memory in binary format.
A
L
L
I
<Execution command response format>
When the Command Is Processed Normally
All image data (binary)
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
All image data size
All image data (binary)
PRECLBSAVEB (Check) / CLBSAVEB (Execute)
Outputting calibration data (binary data)
This command outputs data with the specified calibration number in binary data format.
To execute this command, two types of commands are used, a confirmation command and an execution
command.
For how to execute the command using the confirmation command and the execution command, refer to
Binary Data File Load and Save Commands: p. 183.
<Confirmation command format>
Before calibration data in binary data format is output, a check is performed to determine if the data can be
received by the external device that will receive the data.
P
R
E
C
366
Command Control
M
A
G
E
S
A
CR
Delimiter
Number of bytes of image data to output (integer type)
Image data to output (binary data)
L
B
S
A
V
E
V
E
B CR
Delimiter
Calibration data number
B
Space
Delimiter
(0x20)
CR