Omron FQ2-S Series User Manual page 256

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Save All Image Data
This command saves all image data saved in the Sensor's memory by the logging function to the SD card
inserted in the Touch Finder as ifz data.
The backup data destination and file name are fixed as follows.
• Destination
The following fixed directory on the SD card.
\Sensor name\LOGIMAGE\Number
*
Number is a five digit number starting from 00000. The images are saved in increments of 100 images for each number, and when there
are over 100 images, the directory with the next number is created.
The file name is not case sensitive. The file name extension can be omitted.
• File name
Automatically created as follows.
img_ScnNNN_YYYY_MM_DD-HH_mm_ss(S)_TTTT_XX.ifz
img
ScnNNN
YYYY_MM_DD
HH_mm_ss
(S)
TTTT
XX
*1
The date and time are not recorded in the image data. Therefore, this is not the date and time that the measurement was performed, this is
the date and time the image data file was saved from the Sensor to the Touch Finder SD card by this command.
For example, when performing the 10th measurement with scene 1 after the Sensor's power supply has been turned on, and the execution
time of this command is December 5, 2013, at 22:10:21
img_Scn001_2013_12_05-22_01_21(1)_10_OK.ifz
Command (PLC to Vision Sensor)
First word of com-
mand area
+2
+3
Response (Vision Sensor to PLC)
First word of
response area
+2
+3
+4
+5
254
Command Control
*
Prefix string. The string can be set as desired with the following setting.
(Setup Mode or Run Mode) − [TF settings] − [File format]
Scn + measured scene number (0 to 31)
Date that the image data was saved to the Touch Finder SD card
Time that the image data was saved to the Touch Finder SD card
Image data number (0 to 19)
Number of measurements since the Sensor was started. Reset when the power supply is
turned OFF.
Total judgment (OK/NG)
Bits
12 to 15
8 to 11
4 to 7
0100
0000
0001
0000
0000
0111
Bits
12 to 15
8 to 11
4 to 7
0100
0000
0001
0000
0000
0111
0000
0000
0000
0000
0000
0000
Contents
0 to 3
0000
Command code
0000
Contents
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
*1
*1
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents