3
Set the following items on the display to set expres-
sions.
Item
Description
Expression
Register the expression to use to output multiple data.
Examples:
Const.
Used to insert numbers and symbols into the expression.
Data
Used to select the inspection items for which to output data and insert the parameters to output
into the expression.
Example: Selecting Parameters for the Search Item at Inspection Item 0
Math.
Either of the following two functions can be inserted.
• LPR function (order of the measurement data)
The measurement data is output in order.
Format: LPR(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
• LPC function (order of the detection points)
Data is output for each detected measurement point.
Format: LPC(start_number,number_of_data,data_1, data_2,...data_5)
You can omit data 2 to data 5.
To register something to data 1 and higher, repeat this process.
The settings will be enabled after you restart the Sensor.
● Expression Setting Example
This example registers an expression to output the following inspection results for data 0.
Inspection item: 0 Search
Parameters to output: Position X, Position Y, Reference SX, and Reference SY
Multi-point output setting: Multi-point output Check Box selected, Count = 4
LPR(0,I0.C
,
I0.X,I0.Y,I0.SX,I0.SY)
Function
data_A, data_B...data_d
Number_of_data
(Detection count)
Start_number
Output Results
The data for 16 items (64 bytes) is output in the following order for the expression that is registered for data 0.
*1
Output order
Assigned data
1
I0.X[0] (Position X 1st point)
2
I0.Y[0] (Position Y 1st point)
3
I0.SX[0] (Reference SX 1st point)
4
I0.SY[0] (Reference SY 1st point)
5
I0.X[1] (Position X 2nd point)
FQ2-S/CH User's Manual
for Communications Settings
LPR (0, 3, I0.X, I0.Y)
LPC (0, I0.C, I0.X, I0.Y)
Inspection item: I0. Search
Judgement result: Judgement JG, Correlation: Corre. CR
Control and Output in No-Protocol (TCP) / No-Protocol (UDP)