Timing Chart
Output OR0 to OR31 signals are held until the next judgement output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
Example:
OR0 signal
OR1 signal
*1:
The timing for updating the OR signal is when the measurement results are finalized, regardless of the output settings of the BUSY signal
(BUSY output conditions).
Settings
[In/Out] − [I/O setting] − [I/O setting] − [Output]
1
Press [OUT0].
2
Press [OR2 (Item 2 judgement)].
OR2 output signal was assigned to OUT0.
3
Assign the others in the following manner.
OUT1: OR5
OUT2: OR14
Adjusting the Judgement Output Timing
The output timing of the OR signal or OR0 to OR31 signals can be selected from two modes depending on the
external device.
Selecting the OFF Timing
• Level output (default)
The status of the output OR signal is held until the next OR signal is output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
42
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
ON for 1 ms min.
ON while measure-
ments are being
processed (depends
on BUSY output
conditions)
Overall judgement
(OR output: ON for NG)
Turned ON when individual
judgement is NG.
(OR output: ON for NG)
Turned ON when individual
judgement is NG.
(OR output: ON for NG)
Individual
*1
judgement
NG
Held until the next
judgement result is output
OK
FQ2-S/CH User's Manual