Omron FQ2-S Series User Manual page 388

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Acquire Communication Output Status: 280F 00207020
This command acquires the output status (allowed/prohibited) for all the communications protocol set with the
Set Communication Output Status command.
Command Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Acquired value
386
Command Control
Vision Sensor command code
(4 bytes)
00207020
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Returns the acquired communications protocol status.
1: Output allowed status
0: Output prohibited status
Vision Sensor command code
(4 bytes)
00207020
Acquired value
(4 bytes)
Acquired value
FQ2-S/CH User's Manual