Omron FQ2-S Series User Manual page 110

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

• Command Area
Signal name
EXE
TRIG
ERCLR
DSA
Command code
Command parameter 1
Command parameter 2
Command parameter 3
• Response Area
Signal name
FLG
BUSY
READY
OR
RUN
ERR
GATE
Command code
Response code
Response data
• Output Area
Signal name
Output data 1
Output data 8
● Accessing Communications Areas by Specifying I/O Memory Addresses
AT specifications can be set for variables to individually specify the I/O memory addresses that are assigned in
the communications areas.
1
Setting Tag Sets (Network Configurator)
Specify the tag names in the PLC directly by using the I/O memory addresses that are assigned in the
communications areas. (Output tags are specified for the input connections to the Sensor and input tags
are specified for output connections to the PLC.)
Setting Examples
Output tag: D0
Input tag: D100
108
Controlling Operation and Outputting Data with EtherNet/IP Communications
Variable name
EIPOutput.ControlFlag.F[0]
EIPOutput.ControlFlag.F[1]
EIPOutput.ControlFlag.F[15]
EIPOutput.ControlFlag.F[16]
EIPOutput.CommandCode
EIPOutput.CommandParam1
EIPOutput.CommandParam2
EIPOutput.CommandParam3
Variable name
EIPInput.StatusFlag.F[0]
EIPInput.StatusFlag.F[1]
EIPInput.StatusFlag.F[2]
EIPInput.StatusFlag.F[3]
EIPInput.StatusFlag.F[4]
EIPInput.StatusFlag.F[15]
EIPInput.StatusFlag.F[16]
EIPInput.CommandCodeEcho
EIPInput.ResposeCode
EIPInput.ResposeData
Variable name
EIPInput.OutputData[0]
EIPInput.OutputData[7]