The communications protocol types are defined by the following numbers.
Communica-
Communications type
tions protocol
No.
0
No protocol (Ethernet)
1
No protocol (RS-232C)
2
Parallel I/O
3
Fieldbus
4
Reserved
5
PLC link
Set Communication Output Status
This command sets the output status (allowed/prohibited) of the communications port for all the
communications protocol.
Communications protocols with the output status set to prohibited will no longer output signals after being set
as such.
Command (PLC to Vision Sensor)
First word of com-
mand area
12 to 15
+2
0111
+3
0000
+4
0000
+5
0000
Response (Vision Sensor to PLC)
First word of
response area
12 to 15
+2
0111
+3
0000
+4
0000
+5
0000
FQ2-S/CH User's Manual
for Communications Settings
No-protocol (UDP)
No-protocol (TCP)
EtherNet/IP
PROFINET
PLC Link (SYSMAC)
PLC Link (MELSEC)
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Bits
8 to 11
4 to 7
0 to 3
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
Remarks
Results in an error when specified.
Description
Command code
Communications protocol status to be set
0: Output prohibited status
1: Output allowed status
Description
Command code
The command code for which the response
applies is stored.
Response code
Command execution result
0: OK, FFFFFFFF: NG