Sample Ladder Program
This sample ladder program executes trigger retry when the I/O input mode is Expanded Mode.
Trigger retry is executed at W0.00 ON.
W0.00
Trigger retry execution
W0.00
Trigger retry execution
T0000
OUT1
BUSY
IN5
T0001
BUSY
• I/O Signal Allocations
Signal type
Output signal
Input signals
Note
The time the BUSY signal is ON is the trigger retry execution time.
54
Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
Address
OUT1 (BUSY signal)
CIO 0.01
IN0
CIO 1.08
IN1
CIO 1.09
IN2
CIO 1.10
IN3
CIO 1.11
IN4
CIO 1.12
IN5
CIO 1.15
MOV
When trigger retry execution (W0.00)
#0C00
is turned ON, the command
parameter for sensor restart (001100)
Q:1
is output to Q:1 (IN0 to IN4).
TMHH
0000
If the BUSY signal is OFF five
#5
ms after the command parameter
is output, the trigger retry
execution trigger (IN5) turns ON.
SET
IN5
RSET
W0.00
TMHH
0001
#3000
After being ON for 3000 ms, the
trigger retry execution trigger
(IN5)turns OFF.
RSET
IN5
After trigger retry finishes and the
BUSY signal turns OFF, post trigger
SET
retry processing (W0.01:ON) is
W0.01
executed.