ENERGY SAVER MODES (B044/B045/B046)

6.23 ENERGY SAVER MODES (B044/B045/B046)

6.23.1 MODE TRANSITIONS

When the machine is idle, the energy saver function reduces power consumption
by lowering the fusing temperature. As shown below, the machine can be set to
transition to two different reduced power states, in the following order:
1) Low power mode
2) Auto-off mode
Energy Saver Timer ( x )
Default: 15 min
Standby
Mode
Auto-Off Timer ( y )
Default: 30 min
Above, if the Energy Saver Timer setting is x and the Auto Off Timer setting is y,
then the following operation applies:
• If x < y:
The machine moves into selected low-power mode if all sensors and
components remain inactive for time x, then moves into auto-off mode if
all sensors and components continue inactive for time y-x.
• If x ≥ y:
The machine skips low-power mode and moves directly into auto-off
mode if all sensors and components remain inactive for time y.
Note that during countdown to x or y, the machine may automatically switch into the
preferred application mode (copier/fax) in accordance with the User Tool's Function
Priority and System Reset settings. This has no effect on the power-mode transition
timing.
B129 Series/B044 Series
CÓPIA NÃO CONTROLADA
Machine idle for time x
(where x < y)
"Wake-up" action
Machine idle for time y
(where y < x)
"Wake-up" action
6-66
CÓPIA NÃO CONTROLADA
Rev.11/2004
Low Power Mode
Machine idle for time ( y - x )
(where y > x )
Auto-Off Mode
B046D574.WMF