B044/B045/B046 Models:
CAUTION: To avoid mechanical or electrical damage, do not leave electrical
components on continuously for a prolonged period of time.
1. Access SP5-804.
2. Select the number that corresponds to the component you wish to check (see
the table below), then press OK or
3. Press "1", then press OK or the
4. To interrupt the test, re-enter SP 5-804 and enter a value of "0".
Output Check Table
Number
1
Polygon mirror motor (400 x 400 dpi)
2
Polygon mirror motor (600 x 600 dpi)
3
Main motor
4
Fan motor (slow)
5
Fan motor (fast)