Rev. 11/2004
33. Select the language used in the operation panel as necessary (
Language).
34. Make a full size copy, and check if the side-to-side and leading edge
registrations are correct. If they are not, adjust the registrations.
NOTE 1: The following steps 35 to 44 are for the B130/B168/B169 ONLY:
NOTE 2: For B044/B045/B046 go to step 46:
35. Activate the SP mode (
36. Select Copy SP 5-302-002 (Time) and specify the time difference.
37. Quit the SP mode.
38. Activate the User Tools (
39. Specify the date and time (System Settings > Timer Settings > Set Date/Set
Time).
40. Quit the User Tools.
41. Activate the SP mode.
42. Select Copy SP5-307.
43. Specify the daylight-saving-time settings.
44. B129/B130/B168/B169 Only: Exit the SP Mode now.
45. B044/B045/B046 Only: Enter SP mode (See 5.1 Accessing SP Mode), and run
SP7-825 to initialize the electrical total counter to 0.
NOTE: 1) After selecting SP7-825, enter "1" and then hold down the Original
Type key and press the OK key to initialize the counter. If
initialization is successful, the screen displays "Action completed."
2) SP7-825 is effective only once, at time of machine installation.