SERVICE PROGRAM
5.1.9 OUTPUT CHECK
B129/B130/B168/B169 Models:
Conducting Output Check
CAUTION: To prevent mechanical or electrical damage, do not keep an electrical
component on for extended periods of operation.
1. Select SP5-804.
2. Select the number (see the table below) corresponding to the component.
3. Select "ON."
4. To stop the operation, select "OFF."
Output Check Table
Num.
001
Main Motor Forward
002
Main Motor Reverse
003
Quenching Lamp
004
Toner Supply Clutch Forward
005
Fan Motor High
006
Fan Motor Low
007
Registration Clutch
008
By-pass Feed Clutch
009
Upper Feed Clutch
010
Lower Feed Clutch
017
BK-Lift Motor
020
Duplex Inv Motor Reverse
021
Duplex Inv Motor Forward
024
Duplex Inv Motor Hold
026
Polygon Motor
027
Polygon M/LD
028
LD
029
DF-Transport Motor
031
DF-Feed Clutch
038
Fusing Solenoid
039
Fast Dup Inv M-Rev
When checking Fan Motor High (005) or Fan Motor Low (006) note the following:
• These motors may not respond when the fusing temperature is high.
• Selecting "ON" verifies that one of these motors operates properly. Selecting
"OFF" turns off the motor that you have started by selecting "ON." However, this
does not guarantee that the motor stops properly during normal operation.