Gestetner B130 Service Manual page 160

Table of Contents

Advertisement

Reset–Counters
7808
7808 1
Resets all counters except for the management counters. The management
counters are the counters that are not changed by NVRAM Download (SP5-825-
NVRAM Download (SP5-825-001) in section 5.1.9). When the program
001;
ends normally, the message the message "Completed" is displayed.
7810
Reset–Key Op Code
7810 1
Resets the key operator code. Use SP7-810-1 when the customer has forgotten the
key-operator code. When the program ends normally, the message "Completed" is
displayed, if the program ends abnormally, an error message is displayed. If the
customer forgets the key operator code. To specify a new key-operator code, use
the User Tools: System Settings → Key Operator Tools → Key Operator Code →
On → Enter Key Operator Code.
7832*
Display-Self-Diag
7832 1
Displays the SC codes and the number of their occurrences. Each number is in the
range of 0 to 9999.
Dsply–Info Count
7991*
Displays the total operating time or the total number of operations. The time is
displayed in the following format: day:hour:minute:second.
7991 1
Dsply-Timer Count
The total of the time when the main switch is kept on (excluding the time when the
safety switch is off).
7991 3
Dsply-ID S Work
The total of the time when the ID sensor is working.
7991 4
Dsply-Dev Counter
The total number of paper outputs.
7991 5
Dsply-ID Er Count
The total number of ID-sensor errors.
7992*
Reset-Info Count
7992 1
Reset-Timer Count
Clears the timer counter (SP7-991-001).
7992 4
Reset-Dev Count
Clears the development counter (SP7-991-004).
7992 5
Reset-ID Er Count
Clears the ID sensor error counter (SP7-991-005).