AOF

When AOF is off, the engine controller is unable to start the Night/Off Mode. It is
recommended that the user keep AOF on (
Tools → AOF).

Timers

The engine controller references the Energy Saver Timer to start the Low Power
Mode, and references the Auto Off Timer to start the Night/Off Mode. The user can
set these timers (
The Energy Saver Timer and the Auto Off Timer start at the same time (t
machine ends all jobs, or when the user ends all manual operations. Note that the
Auto Off Timer does not wait for the Energy Saver Timer. If the user specifies a
larger value in the Energy Saver Timer, the Auto Off Timer expires earlier than the
Energy Saver Timer. In a case like this, the Low Power Mode is not activated.
Instead, the engine controller starts the Night/Off Mode when the Auto Off Timer
expires.
Specified value
Energy Saver Timer > Auto Off Timer
Energy Saver Timer = Auto Off Timer
Energy Saver Timer < Auto Off Timer

Recovery

Any of the following operations bring the machine back to the Operating Mode:
• The power switch is pressed.
• Originals are set on the document feeder.
• The platen cover is opened.
SM
CÓPIA NÃO CONTROLADA
ENERGY SAVER MODES OF B129 BASIC MACHINE
→ System Settings → Timer Settings).
Low Power Mode
6-69
CÓPIA NÃO CONTROLADA
→ System Settings → Key Operator
Night/Off Mode
Cannot start
Cannot start
Can start
B129 Series/B044 Series
) when the
0
Can start
Can start
Can start