Gestetner B130 Service Manual page 213

Table of Contents

Advertisement

SERVICE PROGRAM
SP5-XXX (Mode)
5
Mode Number/Name
001
All Indicators On
302*
Date/Time
501*
PM Alarm Mode
1
Interval
2
On/Off
801
Memory All Clear
802
Free Run
803
Input Check
804
Output Check
B129 Series/B044 Series
CÓPIA NÃO CONTROLADA
Sets on all indicators on the operation panel, and causes
the display to blink (empty for five second, all pixels black
for five seconds).
After checking, press
Sets the date and time.
For the year value, you can set the last two digits only.
(The first two digits are fixed at "20".)
You cannot set the seconds value directly. Instead,
the seconds value automatically resets to 0 when you
enter the setting for the minutes value.
Use cursor keys (or OK) to move from field to field
(the selected field flashes), and enter values with the
numeric keys. Your new settings are saved only if you
press OK while the minutes field is selected.
Sets the base PM interval.
[1 ~ 255 / 90 / 1K copies/step]
This setting is meaningful only if SP5-501-2 is set to "1".
Enables/disables the PM alarm for the total number of
prints, copies, and faxes.
[0 = Disable / 1 = Enable]
Resets all SP/UP settings and values to their defaults,
with the exception of plug-and-play settings (SP5-907),
total print counters (SP7-003), and the serial number
setting (SP5-811). (
[0 = No / 1 = Yes]
Before clearing the SRAM, be sure to output an SMC
printout of all current SRAM content. (
This SP mode should generally not be used.
Starts a free run of both the scanner and the printer.
[0: = No / 1 = Yes]
For details about free runs:
After selecting "1", press the OK key (or the
twice to start the free run. Press
Displays the signals being received from a selected
sensor or switch. (
Press
to exit the program.
Turns on a selected electrical component for test
purposes. (
5.1.4)
5-72
CÓPIA NÃO CONTROLADA
Function/[Setting]
or Cancel to exit.
5.1.6)
5.1.7.
to stop the free run.
5.1.3 )
SP5-992).
key)
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B129B045B168B169B046B044

Table of Contents