Memory Clear B044/B045/B - Gestetner B130 Service Manual

Table of Contents

Advertisement

Rev. 11/2004

5.1.7 MEMORY CLEAR B044/B045/B046

Executing a Memory All Clear will reset all SRAM-resident SP and UP settings and
values to their defaults—with the exception of the serial number setting (SP5-811),
the plug-and-play settings (SP5-907), and the total print counters (SP7-003). This
procedure is not for normal use, but may be appropriate if the copier has
malfunctioned as a result of a problem with its SRAM.
1. Before clearing the memory clear, you should do both of the following to save
current SRAM data (if possible).
Print a complete SMC printout using SP5-992. Be sure to select all "2"
("All") for the printout type. (
Upload the data to a flash memory card using SP5-824. (
2. Access SP5-801.
3. Hold down the Original Type key and press the OK key (or
the clear. If the clear is successful, the display shows "Action completed". If it
fails, the display shows "Error!!!".
4. Turn the main switch off and back on.
5. If you save SRAM data to a flash-memory card, try downloading the data back
into the machine (
procedure.
If you did not save SRAM data to a flash memory card, or if you were unable to
download the saved data, then continue as follows.
6. Carry out printer and scanner registration and magnification adjustments.
(
3.13)
7. Carry out auto-scanner (white-level) adjustment, using SP4-908.
8. Refer to the SMC printout, and re-enter any values that differ from the factory
settings.
9. Check the copy quality, and carry out any necessary adjustments.
SM
CÓPIA NÃO CONTROLADA
5.1.5)
5.1.9). If the download is successful, this completes the
5-85
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM
5.1.9)
) key) to execute