System Switch 06
No.
FUNCTION
0
Use of the Stop key during
memory transmission
0: Disabled 1: Enabled
1–3
Not used
4
Use of the Stop key during
memory transmission
0: Disabled 1: Enabled
5–7
Not used
System Switch 07 - Not used (do not change any of these settings)
System Switch 08 - Not used (do not change any of these settings)
System Switch 09
No.
FUNCTION
0
Not used
1
Inclusion of communications in the
Journal when no image data was
exchanged.
0: Disabled 1: Enabled
2
Automatic error report printout
0: Disabled 1: Enabled
3
Print error code on error report
0: No 1: Yes
4
Not used
5
Power failure report
0: Disabled 1: Enabled
6
Conditions for printing the protocol
dump list
0: Print for all communications
1: Print only when there is a
communication error
7
Priority given to various types of
remote terminal ID when printing
reports
0: RTI > CSI > Dial label > Tel.
Number
1: Dial label > Tel. number > RTI >
CSI
SM
CÓPIA NÃO CONTROLADA
1: The Stop key can be used to halt memory
transmissions. However, users might
accidentally cancel another person's
memory transmission in progress.
Do not change these settings.
1: The Stop key can be used to halt memory
transmissions. After pressing the Stop key,
a message (STOP & CLR FILE?) appears
on the LCD.
Do not change these settings.
Do not change the setting.
0: The Journal lists communications that
reached phase C (message TX/RX) of the
T.30 protocol.
1: The Journal lists communications that
reached phase A (call setup) of T.30
protocol. This includes telephone calls.
0: Error reports are not printed.
1: Error reports will print automatically after all
failed communications, excluding polling
reception and immediate transmissions.
1: Error codes are printed on the error reports.
Do not change the setting.
1: A power failure report automatically prints
after the power is switched on if a fax
message disappears from memory when
the power was turned off last.
This switch becomes effective only when
system switch 00 bit 6 is set to 1.
1: Set this bit to 1 when you wish to print a
protocol dump list only for communications
with errors.
This bit determines which set of priorities the
machine uses when listing remote terminal
names on reports.
Dial Label: The name stored with the
Quick/Speed Dial number by the user.
5-11
CÓPIA NÃO CONTROLADA
BIT SWITCHES
COMMENTS
COMMENTS
B465